FR | EN | DE
Home > Produkte > Nuclear Industry > Dosimetry systems
Produktpalette
Nuclear Industry

Dosimetry systems

LMF3

Multifunctional reader for Saphydose Gamma i operational dosimeter / teledosimeter

The LMF3 electronic dosimeter reader is the last generation of dosimeter readers developed by Saphymo. It is the worthy successor of the LMF2, which is operating in every EDF French nuclear plant.

The LMF3 is an intelligent self-learning system that allows to read and configure dosimeters, and to send information to the dosimetric management system, in order to regulate access to a controlled area regarding technical criteria.

It can command to an access control device (partial door, tripod, berrier...) or a contamination control portal, and be equiped with a badge reader, a bar code reader and/or a large touch screen that offers extra user-friendly functions.

Depending on the situation, it can also replace the LMF2 reader.

Spezifikationen:

Configurations
Many configurations available (input, output, initialization…)
Signals
5 signal lamps to indicate the operating state
Display
2 lines of 20 alphanumeric characters each
Optional display
Touch screen for a better user-friendliness
Multilingual
Language can be selected via the touch screen
Memorization
More than 10 000 cutovers
Installation
In a rack or on a wall
Operating temperature
From - 10 to + 50 °C
Links
Double TCP/IP link available (redundancy)
Settings
Remote setting and updating of the LMF 3

technisches Datenblatt :

pdf LMF3 datasheet [09/10/2015 10:12] 314 Ko.
Kontakt Saphymo